Description / Abstract:
Introduction
Intent
The intent of this procedure is to determine the inside diameter
of the ferrule hole in an optical fiber connector ferrule.
Accuracy and precision
The precision of the method is affected by the incremental
differences in the outer diameters of the calibrated wire set used
for the measurement. The accuracy of the method is controlled by
the calibration of the calibrated wire set.
Applications
This procedure is applicable to all optical fiber
connectors.